CDN Model numbers | Required Calibration Accessories | ||
---|---|---|---|
Calibration Adaptor | Calibration Resistor | Termination | |
Coupling onto Power lines (type: CDN M1, M2, M3, M4, M5) | |||
16 Amperes | |||
CD20016 | CA M2 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CD30016 | CA M3 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CD40016 | CA M4 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CD50016 | CA M5 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
32 Amperes | |||
CD10032 | Included with CD10032 | CR00100CD (Includes 2) | TL50050 |
CD20032 | CA M2-32 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CD30032 | CA M3-32 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CD40032 | CA M4-32 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CD50032 | CA M5-32 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
50 Amperes | |||
CD20050 | CA M2-50 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CD30050 | CA M3-50 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CD40050 | CA M4-50 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CD50050 | CA M5-50 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
100 Amperes | |||
CD20100 | CA M2-100 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CD30100 | CA M3-100 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CD40100 | CA M4-100 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CD50100 | CA M5-100 (Includes 2) | CR00100CD (Includes 2) | TL50050 |
CDN Model numbers | Required Calibration Accessories | |||||
---|---|---|---|---|---|---|
Calibration Adaptor | Calibration Resistor | Termination | ||||
Coupling onto Power lines (type: CDN M1, M2, M3, M4, M5) | ||||||
200 Amperes | ||||||
CD20200 | CA M2-200 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CD30200 | CA M3-200 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CD40200 | CA M4-200 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CD50200 | CA M5-200 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
300 Amperes | ||||||
CD20300 | CA M2-300 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CD30300 | CA M3-300 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CD40300 | CA M4-300 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CD50300 | CA M5-300 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
Coupling onto Unscreened Balanced Lines | ||||||
CDN AF2 | CA AF2 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CDN10K AF2 | CA AF2 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CDN AF3 | CA AF3 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CDN AF4 | CA AF4 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CDN10K AF4 | CA AF4 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CDN AF8 | CA AF8 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
Coupling onto Screened Data Lines | ||||||
CDN S2 | CA S2/S3/S4/S9 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CDN S3 | ||||||
CDN S4 | ||||||
CDN S9 | ||||||
CDN10K S9 | ||||||
CDN S15 | CA S15 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CDN S25 | CA S25 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
Coupling onto Unscreened Balanced Pairs | ||||||
CDN T2 | CA T2 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CDN T4 | CA T4 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CDN T8 | CA T8 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
Coupling on Coaxial Cable Shields | ||||||
CDN C1050 (50 Ω) | CA C1050 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CDN C1075 (75 Ω) | CA C1075 (Includes 2) | CR00100CD (Includes 2) | TL50050 | |||
CD10K20016 | CA M2 | CR00100CD (Includes 2) | TL50050 | |||
CD10K30016 | CA M3 | CR00100CD (Includes 2) | TL50050 |
BCI Probe | Required Calibration Accessories | ||
---|---|---|---|
Calibration Fixture | Calibration Resistor | Termination | |
IEC Commercial Testing | |||
BI00250 | CF00250 | CR00100BC (Includes 2) | TL50050 |
Military testing to MIL-STD-461D/E CS114 and DO160D/E (10 kHz ? 400 MHz) | |||
BI00400 | CF00400 | N/A | TL50050 |
Automotive testing 1 MHz - 400 MHz | |||
BI00401 | CF00400 | N/A | TL50050 |
EM Clamp | Required Calibration Accessories | ||
---|---|---|---|
Calibration Fixture | Calibration Resistor | Termination | |
IEC Commercial Testing | |||
EM10123 | EM10123CF | Built into fixture | TL50050 |
EM10132 | EM10132CF | Built into fixture | TL50050 |
SPECIFICATION | ATTENUATORS |
---|---|
IEC 61000-4-6 & Related Product Standards | AF06250, AF10050, AF20050 |
MIL STD CS114 & DO160 | AF06250, AF10050, AF20050 |
Automotive BCI Specifications | AF10050 , AF20050 |
SPECIFICATION | Probe/s |
---|---|
IEC 61000-4-6 & Related Product Standards | BP00250, BP00251 |
MIL STD CS114 & DO160 | BP00400 & BP00100 |
Automotive BCI Specifications | BP00400 |